Napco – GEM-P1664 Control Panel8 hybrid zones on-board including two 2-wire fire zones in large, locking enclosure (12.5 x 14 x 3.75)With multiplexing, can accommodate up to 64 EOL zones (from alpha keypads or multiplex modules, including the low-cost GEM-EZM4/8 Expansion Module).Programmable partitioning for 4 areasUp to 64 usersUses all the standard Gemini crystal-control wirelessUses all the standard Gemini keypads, new DK-Series door-style keypads and multifunction VPS Series talking keypads (shown above)Two money-saving paks with custom alpha door keypad GEMP1664DK1PK; or with multifunction GEMK1VPS keypad with built-in talking voice, PIR and UL siren, GEMP1664VPSPKThe GEM-P1664 Hybrid 8 to 64-Zone Control/Communicator features 8 zones expandable to 64 zones with multiplexing and supports all standard Gemini RP and K-Series Keypads, plus new Gemini DK-Series Door-Style Keypads and new VPS Series talking multifunction keypads, as well as reliable, NAPCO Gemini crystal-control transmitters and receivers, too. Supporting up to 64 user codes and 16 relays, the GEM-P1664 control features easy menu drivenSelf-Programming Plus keypad programming (for all zones), which includes new alpha keypad question-prompts, even for setting test timer, fire zones and exit/entry and follower zones. Additionally, the panel can be remote up/downloaded using easy-to-use NAPCO Quickloader Software.FEATURES8 Hardwire/Wireless Zones on boardUp to 64 zones with multiplex expansion including 2 two 2-wire fire zonesWith multiplexing, can accommodate up to 64 EOL zones (from custom alpha keypads or multiplex modules)EZ Programming2 More comprehensive, menu-driven programming for all zones plus test timer.Up to 64 user codesUp to 4 areas3 on-board outputs, up to16 external relay outputs (RM3008s).Up to 2 NAPCO helically-filtered, crystal-control RF receiversInterior bypass group with programmable automatic interior bypass400 event logAuto ArmUses up to 7 of any of the Classic/RP-, K-Series or DK-Door Style Stay & Away keypadsProgrammable telephone line cut supervision with delay3 Keypad panics (F, P, A)Supports all major communicator formats, including: 4/2, SIA, 4+2 and Point ID, plus pagerBackup/double/split reporting; three 20-digit telephone numbersDynamic battery testReports alarms, restores and troubles by zone.2 programmable entry delay timesChime by zone8 EOL burglary zones programmable for area, E/E delay, interior, follower, day zone, chime, fire options, sensor watch, swinger shutdown, cross zoning , etc.Multiplex Expandability with GEM EZM4/8 or GEM EZM8 zone expansion modulesQuickloader up/downloading, including unique unattended methodChoice of RF receiversPartitioning by areaEvent log with open/close suppressionEvent log viewable at keypad (total log, burglar alarm log, fire alarm log, system trouble log, o/c log)Cellphone-style keypad programming of zone descriptions ( text)Programmable 50Hz Clock SettingProgrammable Daylight Savings TimeProgrammable Security Bypass (code required for bypass)Un-Bypassing while disarmed (code required)Temperature Display at Keypad (-30 to 600C Celsius or -22 to 1400F Fahrenheit) with optional GEM-TEMP64 Indoor/Outdoor Temperature Sensor (Note: Keypad Temperature Display replaces Date on Display and is for use with custom alphanumeric keypads, only, i.e., DK1, K1, RP1)Programmable High/Low Temperature Alarm Reporting (requires feature enabled; zone 6)24 Hour day zone troubleProgrammable Swinger Shutdown (2 or 3 activations selectable)Zone Anding/Cross Zoning (Grouping of zones in which sequential zone activation is required to generate an alarm)Compatible Napco keypads with the new Gem-P1664 panelClick and drag to moveSPECIFICATIONSInput Power: 16.5-18.0 VAC via Class 2 Plug-In 20VA, 40VA or 50VA TransformerLoop Current: 3mA; 5mA for 2-wire smoke-detector zonesLoop Resistance: 300 Ohm max.; 50 Ohm for 2-wire smoke detector zonesAlarm Voltage Output: 1; Programmable Negative Outputs: 2Auxiliary Power Output: 11.7-12.5 VDCRemote Power Output: 12 VDC regulatedCombined Standby Current – See WI1501UL Listings & Compliances:Household Burglar Alarm System Units: UL1023Household Fire Warning System Units: UL985Security Industry Association (SIA) False Alarm Reduction Standard CP-01ORDERING INFORMATIONGEM-P1664 Panel New! 8 to 64 zone, 4 partition control panel in large locking enclosure, 12.5 x 14 x 3.75. (Plug-in AC transformer, supplied).GEM-K1VPS talking keypad New! Labor-saving, multifunction, talking custom alphanumeric keypad with built in pet-PIR, UL siren, and spoken voice-prompts. Dual-line blue display and built in 4-zone expansion module. Stay/away user functionality.GEMP1664VPSPK New! Money-saving pak with P1664 panel and multifunction talking custom alpha blue backlit keypad with built-in 4 zone expander, pet PIR, UL siren. Stay/away user functionality. Supplied AC transformer.GEM-DK1CA door keypad New! Door-style deluxe custom alphanumeric dual-line blue display keypad with built in 4-zone expansion module. Stay/away user functionality.GEMP1664DK1PK New! Money-saving pak with P1664 panel and door-style DK1CA custom alpha blue backlit keypad with built-in 4 zone expander. Stay/away user functionality. Supplied AC transformer.
Napco Gemini 1664 Control Panel
$198.00
Out of stock
SKU: 1001012GEM1664
Category: Home Security Products
Only logged in customers who have purchased this product may leave a review.
Related products
Home Security Products
$97.00
Home Security Products
$161.00
Home Security Products
GE Surface-Mount Magnetic Door & Window Alarm Contact w/Screw Terminals
$19.00
Home Security Products
$215.00
Home Security Products
$250.00
Home Security Products
Honeywell Commercial Wireless Hold-Up Switch with Transmitter 5869
$89.00
Home Security Products
Honeywell Touchscreen Security Keypad and Home Controller with Integrated Wi-Fi
$450.00
Home Security Products
$49.00
Reviews
There are no reviews yet.